The influence of ODM technique on the radiation dose received by patients during head CT scan

Content
Title variants
Languages of publication
EN
Abstracts
EN
Introduction. Computed tomography (CT) is inexpensive radiological examination of high diagnostic effectiveness. However, common use of CT tests has led to increased exposure to ionizing radiation in the population. Aim. To assess the effect of organ dose modulation (ODM) technique on the radiation dose received by patients during head CT scan. Material and methods. A retrospective analysis of 120 tests in two groups of patients who had CT scans without and with ODM. Every group consisted of 60 people (30 women and 30 men in each). The ability to perform tests in two algorithms (without and with ODM) resulted from the fact that after installing the apparatus, tests were carried out using standard technique, and only then the ODM function was launched. Results. We found that during examinations with ODM, patients received a reduced dose of ionizing radiation. The mean DLP value with ODM is 9.4% lower than the mean DLP value without ODM by comparing the tests with and without contrasting agent. The mean DLP value obtained in men using ODM was 11.9% lower than the mean dose without ODM, and in women this difference was 6.6%. Conclusion. The mean DLP value received by men with ODM was by 11.9% lower than the mean dose without ODM, and in women this difference was 6.6%. Patients receive a lower dose both in tests with and without a contrasting agent compared to the tests where ODM was not used. A statistical significance of the obtained results was found.
Year
Issue
3
Pages
198-203
Physical description
Contributors
  • Department of Electroradiology, Faculty of Medicine, University of Rzeszow, Rzeszow, Poland
  • Department of Electroradiology, Faculty of Medicine, University of Rzeszow, Rzeszow, Poland
  • Clinical Radiology and Diagnostic Imaging Department, Regional Hospital No.2 in Rzeszow, Rzeszow, Poland
  • Department of Electroradiology, Faculty of Medicine, University of Rzeszow, Rzeszow, Poland
  • Clinical Radiology and Diagnostic Imaging Department, Regional Hospital No.2 in Rzeszow, Rzeszow, Poland
author
  • Department of Electroradiology, Faculty of Medicine, University of Rzeszow, Rzeszow, Poland
  • Clinical Radiology and Diagnostic Imaging Department, Podkarpackie Oncology Centre Regional Hospital No.1 in Rzeszow, Rzeszow, Poland
  • Department of Electroradiology, Faculty of Medicine, University of Rzeszow, Rzeszow, Poland
  • Center for Innovative Research in Medical and Natural Sciences, Faculty of Medicine, University of Rzeszow, Rzeszow, Poland
author
  • Department of Electroradiology, Faculty of Medicine, University of Rzeszow, Rzeszow, Poland
  • Clinical Radiology and Diagnostic Imaging Department, Regional Hospital No.2 in Rzeszow, Rzeszow, Poland
References
Document Type
Publication order reference
YADDA identifier
bwmeta1.element.mhp-b2aa6f93-d2d4-4ec6-8c70-bcffbdcd22b7
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.