Charakterystyka fizyczna i chemiczna osadów korozyjnych w rurach żelaznych eksploatowanych w obecności przepływu wody

Content

Title variants

EN
Physical and chemical characteristics of corrosion deposits in iron pipes operated in presence of water flow

Languages of publication

Abstracts

EN
The presented paper contains issues related to corrosion of water supply lines formed in cast iron and steel. This process can manifest in different ways, including pipe degradation, release of iron by-products, water flow restriction, microbial growth and the reduction of drinking water safety for consumers, which present a significant threat to water supply safety. The aim of the paper was to show changes that emerged in pipes formed in grey cast iron and steel as a result of potable water flow depending on the duration of their use. The corrosion scales from old water pipe lines were analyzed for their structure and composition. The description of the test methodology presents the procedure regarding, analysis of the inner and outer coating with the use of scanning equipment, and chemical analysis of the corrosion sludge. In this study, corrosion products were carefully collected from four old, corroded iron pipes made of different materials – gray cast iron and steel. It can be concluded that scale characteristics, including micromorphology, porosity and composition, vary significantly due to different pipe materials and times operating. Characteristics of corrosions scales sampled from different pipe segments show obvious differences, both in physical and chemical aspects. Corrosion scales were found highly amorphous. Diverse results can be observed in the case of the test of inner and outer surface of water supply pipes with the use of scanning equipment. The highest quantity of corrosion pits in the structure were present in the line formed in grey cast iron no. 2, while the deepest pits – over 14 mm – were recorded in steel pipe no. 4. Lines with the most reduced cross-section include steel pipe no. 3, which was characterized by presence of sludge sized over 26 mm. When considering the issue of the chemical composition of the formed corrosion sludge, particular attention must be drawn to the elements that may penetrate into water as a result of its flow, thus causing a considerable deterioration of its quality in chemical and physical terms. Among the major constituent elements of the deposits, iron was most prevalent followed, in the order of decreasing prevalence, by silicon, aluminum, sulfur, calcium, manganese, magnesium. Consequently, characterization of corrosion scales is indispensable to water quality protection.

Year

Volume

Pages

30-40

Physical description

Dates

published
2022

Contributors

  • University of Bielsko-Biala / Akademia Techniczno-Humanistyczna w Bielsku-Białej
  • University of Bielsko-Biala / Akademia Techniczno-Humanistyczna w Bielsku-Białej

References

  • Baig S., Lou Z., Baig M., Qasim M., Shams D., Mahmood Q., Xinhua Xu X. 2017. Assessment of tap water quality and corrosion scales from the selected distribution systems in northern Pakistan. Environmental Monitoring and Assessment, 189: 194.
  • Benson A., Dietrich A., Gallagher D. 2012. Evaluation of iron release models for water distribution systems. Critical Reviews in Environmental Science and Technology, 42, 44–97.
  • Cui Y., Liu S., Smith K., Hu H., Tang F., Li Y., Yu K. 2016a. Stainless steel corrosion scale formed in reclaimed water: Characteristics, model for scale growth and metal element release. Journal of Environmental Sciences, 48, 79–91.
  • Cui Y., Liu S., Smith K., Yu K., Hu H., Jiang W., Li Y. 2016b. Characterization of corrosion scale formed on stainless steel delivery pipe for reclaimed water treatment. Water Reseach, 88, 816–825.
  • Dobrzański L., Dobrzańska-Danikiewicz A. 2011. Obróbka powierzchni materiałów inżynierskich. Rozdział 8 – Zmiany struktury i własności powierzchni materiałów inżynierskich w wyniku eksploatacji. Open Access Library, 5, 368–416.
  • Gerke T., Maynard J., Schock M., Lytle D. 2008. Physiochemical characterization of five iron tubercles from a single drinking water distribution system: Possible new insights on their formation and growth. Corrosion Science, 50, 2030–2039.
  • Gerke T., Little B., Luxton T., Scheckel K., Maynard J. 2013. Strontium concentrations in corrosion products from residential drinking water distribution systems. Environmental Science & Technology, 47, 5171–5177.
  • Guo P., Callagon La Plante E., Wang B., Chen X., Balonis M., Bauchy M., Sant G. 2018. Direct observation of pitting corrosion evolutions on carbon steel surfaces at the nano-to-microscales. Scientific Reports, 8: 7990.
  • Jin J., Wu G., Guan Y. 2015. Effect of bacterial communities on the formation of cast iron corrosion tubercles in reclaimed water. Water Research, 71, 207–218.
  • Li M., Liu Z., Chen Y., Hai Y. 2016. Characteristics of iron corrosion scales and water quality variations in drinking water distribution systems of different pipe materials. Water Research, 106, 593–603.
  • Li M., Liu Z., Chen Y. 2018a. Physico-chemical characteristics of corrosion scales from different pipes in drinking water distribution systems. Water, 10, 931–945.
  • Li G., Ding Y., Xu H., Jin J., Shi B. 2018b. Characterization and release profile of (Mn, Al)-bearing deposits in drinking water distribution systems. Chemosphere,197, 73–80.
  • Liu J., Shentu H., Chen H., Ye P., Xu B., Zhang Y., Bastani H., Peng H., Chen L., Zhang T. 2017. Change regularity of water quality parameters in leakage flow conditions and their relationship with iron release. Water Research, 124, 353–362.
  • Lytle A., Tang M., Francis A., O'Donnell A., Newton J. 2020. The effect of chloride, sulfate and dissolved inorganic carbon on iron release from cast iron. Water Research, 183: 116037.
  • Norma PN-EN ISO 15350:2010 Stal i żelazo - Oznaczanie całkowitej zawartości węgla i siarki - Metoda absorpcji w podczerwieni po spaleniu w piecu indukcyjnym (metoda rutynowa). Data publikacji: 09-06-2010.
  • Peng C.Y, Korshin G.V., Valentin R.L., Hill A.C., Friedman M.J., Reiber S.H. 2010. Characterization of elemental and structural composition of corrosion scales and deposits formed in drinking water distribution systems. Water Research, 44, 4570–4580.
  • Peng C., Hill A., Friedman M., Valentine R., Larson G., Romero A., Reiber S., Korshin G. 2012. Occurrence of trace inorganic contaminants in drinking water distribution systems. Journal American Water Works Association, 104, 181–193.
  • Sheng D., Zhu S., Zhang W., Bu L., Wu Y., Wanga J., Zhou S. 2021. Degradation of carbamazepine and disinfection byproducts formation in water distribution system in the presence of copper corrosion products. Chemosphere, 282: 131066.
  • Świetlik J., Raczyk-Stanisławiak U., Piszora P., Nawrocki J. 2012. Corrosion in drinking water pipe: the importance in green ruts. Water Research, 46, 1–10.
  • Trueman B., Gagnon G. 2016. Understanding the role of particulate iron in lead release to drinking water. Environmental Science & Technology, 50, 9053–9060.
  • Wang H., Masters S., Edwards M., Falkinham J., Pruden A. 2014. Effect of disinfectant, water age, and pipe materials on bacterial and eukaryotic community structure in drinking water biofilm. Environmental Science & Technology, 48, 1426–1435.
  • Yang F., Shi B., Gu J., Wang D., Yang M. 2012a. Morphological and physicochemical characteristics of iron corrosion scales formed under different water source histories in a drinking water distribution system. Water Research, 46, 5423–5433.
  • Yang F., Shi B., Wang D., Gu J., Cao N. 2012b. Effect of water chemistry changes on iron release and corrosion scale properties of old cast iron pipes. China Water & Wastewater, 28, 23, 59–64.
  • Yang F., Shi B., Bai Y., Sun H., Lytle D., Wang D. 2014. Effect of sulfate on the transformation of corrosion scale composition and bacterial community in cast iron water distribution pipes. Water Research, 59, 46–57.
  • Zhang H., Liu D., Zhao L., Zhang X., Wang J., Chen Ch. 2020a. Corrosion mechanisms of ductile iron pipes in water distribution system: impacts of ionic strength and cement mortar lining coverage. Desalination and Water Treatment, 197, 237–248.
  • Zhang H., Zhao L., Liu D., Wang J., Zhang X., Chen Ch. 2020b. Early period corrosion and scaling characteristics of ductile iron pipe for ground water supply with sodium hypochlorite disinfection. Water Research, 176: 115742.
  • Zhang H., Liu D., Zhao L., Wang J., Xie S., Liu S., Lin P., Zhang X., Chen C. 2022. Review on corrosion and corrosion scale formation upon unlined cast iron pipes in drinking water distribution. Journal of Environmental Sciences, 117, 173–189.

Document Type

Publication order reference

Identifiers

Biblioteka Nauki
2163400

YADDA identifier

bwmeta1.element.ojs-doi-10_53052_pjmee_2022_4_04
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.