Full-text resources of CEJSH and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

Results found: 2

first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  łączność konwencjonalna
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Background: The assessment of electromagnetic field distribution near radiophones and their use warranted an analysis of thermal exposure hazards and related health effects, based on i.e. numerical calculations of specific energy absorption rate (SAR). Materials and Methods: The investigation concerned radiophones of conventional and trunked communication systems. Electromagnetic hazards assessment involved numerical simulations of SAR inside users' models (male and female) for 5 radiophones locations - near the ear, arm, chest, hip and face. Results: Maximum SAR (10 g) values depend on radiophone type, output power and locations. Near the chest, hip and face they are 6-, 2- and 2-fold higher than for location near the ear. SAR (10 g) may exceed Directive 2013/35/EU limits at maximum (4 W) output power of conventional radiophones, and the distance between antenna and worker's body shorter than 5 cm. SAR (10 g) values near trunked radiophones do not exceed 35% of the Directive limits. The Polish safety and health regulations in particular cases of radiophones use and local exposure may not guarantee the compliance with Directive 2013/35/EU requirements, i.e. SAR (10 g) may locally exceed exposure limit values (ELVs) during exposure to electromagnetic fields of hazardous, and even intermediate zones. Conclusions: It was demonstrated that exposure of trunked radiophones users does not exceed the limits laid down in the Polish safety and health regulations and Directive 2013/35/EU, however, in particular scenarios of the conventional radiophones use overexposure can be observed. The results showed that in exposure to electromagnetic field emitted by sources located near workers' body there is a need for more detailed analysis of the compliance of Polish safety and health regulations with Directive 2013/35/EU requirements. Med Pr 2013;64(6):817–827
PL
Wprowadzenie: Ocena rozkładu pola elektromagnetycznego w otoczeniu radiotelefonów i warunki ich eksploatacji uzasadniają analizę zagrożeń wynikających ze skutków termicznych ekspozycji. Oceniane są one na podstawie obliczeń numerycznych współczynnika szybkości pochłaniania właściwego energii (SAR). Materiały i metody: Badaniami objęto radiotelefony przenośne konwencjonalnego i trankingowego systemu łączności. Ocenę zagrożeń elektromagnetycznych wykonano w oparciu o symulacje numeryczne SAR w modelach ciała użytkowników radiotelefonów (mężczyzny i kobiety) przy 5 lokalizacjach radiotelefonu - przy uchu, ramieniu, klatce piersiowej, biodrze i twarzy. Wyniki: Wartości maksymalne SAR (10 g) zależą od typu radiotelefonu, jego mocy wyjściowej i lokalizacji - przy klatce piersiowej, biodrze i twarzy wartości są odpowiednio: 6-, 2- i 2-krotnie większe niż dla lokalizacji przy uchu. Przy maksymalnej mocy wyjściowej radiotelefonów systemu konwencjonalnego (4 W) mogą one przekroczyć limity Dyrektywy 2013/35/UE przy odległości anteny mniejszej niż 5 cm od ciała użytkownika. Przy radiotelefonach systemu trankingowego wartości SAR (10 g) nie przekraczają 35% wartości dopuszczalnej. Spełnienie wymagań polskich przepisów w niektórych warunkach korzystania z radiotelefonów i ekspozycji miejscowej może nie zapewniać zgodności z wymaganiami Dyrektywy 2013/35/UE, tzn. SAR (10 g) może lokalnie przekraczać GPO (graniczny poziom oddziaływania) podczas narażenia na pola strefy zagrożenia, a nawet pośredniej. Wnioski: Wykazano, że użytkownicy radiotelefonów systemu trankingowego nie podlegają ekspozycji przekraczającej wymagania prawa pracy w Polsce i Dyrektywy 2013/35/UE, natomiast w niektórych scenariuszach wykorzystania radiotelefonów systemu konwencjonalnego narażenie je przekracza. Wykazano również konieczność bardziej szczegółowej analizy zgodności polskich przepisów z wymaganiami Dyrektywy 2013/35/UE, dotyczącej narażenia miejscowego przy źródłach pola elektromagnetycznego zlokalizowanych bezpośrednio przy ciele pracownika. Med. Pr. 2013;64(6):817–827
EN
Background: The activities of rescue and uniformed services require the use of wireless communication devices, such as portable radiophones. Assessment of workers' exposure to electromagnetic fields emitted by radiophones is important in view of occupational safety and health (OSH), legislation requirements and reports on possible adverse health effects in users of devices emitting radiofrequency electromagnetic field. Materials and Methods: In this study 50 portable radiophones of conventional and trunked communication systems were investigated. The assessment of electromagnetic hazards to users involved unperturbed electromagnetic field measurements near radiophones' antennas. Results: The electric field strength corresponding to the occupational exposure level (fields of so-called safety zones established by OSH legislation in Poland) was measured at a distance of 45-65 cm from the portable radiophones antennas of conventional system and 75-95 cm from antennas of trunked system radiophones, depending on their type and mode of work. The assessment was based on the averaged results of series of measurements. The electric field strength exceeding action levels defined by Directive 2013/35/EU was found up to 15 cm from radiophone antennas of conventional system and up to 10 cm from the antennas of trunked system radiophones. Conclusions: Taking into account the range of safety zones and the use of portable radiophones near the body, their users should be classified into the group of workers occupationally exposed to electromagnetic fields. Electromagnetic field measurement results and typical conditions of using portable radiophones justify theneed for additional assessment of electromagnetic hazards - the analysis of compliance with relevant exposure limit values provided by Directive 2013/35/EU. Med Pr 2013;64(5):671–680
PL
Wprowadzenie: Funkcjonowanie służb ratunkowych i mundurowych wymaga wykorzystania urządzeń łączności bezprzewodowej, takich jak radiotelefony. Ocena narażenia pracowników na wytwarzane przez nie pola elektromagnetyczne jest istotna ze względu na wymagania prawa pracy, a także doniesienia literaturowe dotyczące możliwych zagrożeń zdrowia użytkowników urządzeń, które emitują pole elektromagnetyczne o częstotliwościach radiowych. Materiały i metody: Badaniami objęto 50 radiotelefonów przenośnych konwencjonalnego i trankingowego systemu łączności. Zagrożenia elektromagnetyczne dla użytkowników oceniono z wykorzystaniem wyników pomiarów pierwotnego pola elektromagnetycznego, przeprowadzonych w otoczeniu anten radiotelefonów. Wyniki: Pole elektryczne o natężeniu odpowiadającym ekspozycji zawodowej (tj. według wymagań polskiego prawa pracy - ekspozycji na pola tzw. stref ochronnych) zmierzono w odległości dochodzącej do: 45-65 cm od anten radiotelefonów pracujących w systemie konwencjonalnym i 75-95 cm od radiotelefonów systemu trankingowego, zależnie od ich typu i trybu pracy - ocena na podstawie średnich wyników wykonanych serii badań. Pole elektryczne o natężeniach przekraczających tzw. interwencyjny poziomom narażenia, określony w Dyrektywie 2013/35/UE, stwierdzono w odległości do ok. 15 cm od anteny radiotelefonów systemu konwencjonalnego i do ok. 10 cm od radiotelefonów systemu trankingowego. Wnioski: Z uwagi na zasięg stref ochronnych i użytkowanie radiotelefonów przenośnych bezpośrednio przy ciele ich użytkownicy powinni być zaliczani do grupy pracowników, którzy podlegają ekspozycji zawodowej na pola elektromagnetyczne. Wyniki wykonanych pomiarów pola elektromagnetycznego oraz typowe warunki użytkowania radiotelefonów uzasadniają konieczność przeprowadzenia dodatkowej oceny zagrożeń elektromagnetycznych - zbadania zgodności z tzw. granicznym poziomem oddziaływania określonym Dyrektywą 2013/35/EU. Med. Pr. 2013;64(5):671–680
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.