Full-text resources of CEJSH and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

Results found: 2

first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  Legionella
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Background: The frequency of respiratory symptoms in workers exposed to water aerosol was evaluated along with the preliminary assessment of microbiological contamination of air and water used in glass processing plants. Material and Methods: A questionnaire survey was conducted in 131 workers from 9 glass processing plants. Questions focused on working conditions, respiratory symptoms and smoking habits. A pilot study of air and water microbiological contamination in one glass processing plant was performed. Water samples were tested for Legionella in accordance with EN ISO 11731-2:2008 and for total colony count according to PN-EN ISO 6222:2004. Air samples were tested for total numbers of molds and mildews. Results: During the year preceding the survey acute respiratory symptoms occurred in 28.2% of participants, while chronic symptoms were reported by 29% of respondents. Increased risks of cough and acute symptoms suggestive of pneumonia were found among the respondents working at a distance up to 20 m from the source of water aerosol compared to other workers (OR = 2.7), with no difference in the frequency of other symptoms. A microbiological analysis of water samples from selected glass plant revealed the presence of L. pneumophila, exceeding 1000 cfu/100 ml. The number of bacteria and fungi detected in air samples (above 1000 cfu/m³) suggested that water aerosol at workplaces can be one of the sources of the air microbial contamination. Conclusions: The questionnaire survey revealed an increased risk of cough and acute symptoms suggestive of pneumonia in the group working at a shortest distance form the source of water aerosol. Med Pr 2013;64(1):47–55
PL
Wstęp: Przedmiotem badań była ocena częstości występowania dolegliwości ze strony układu oddechowego osób narażonych na aerozol wodny w zakładach przemysłowych oraz wstępna ocena skażenia mikrobiologicznego powietrza i wody technologicznej. Materiał i metody: Opracowano ankietę, która zawierała pytania ukierunkowane na warunki pracy oraz występowanie objawów zmian w układzie oddechowym, które mogą sugerować zapalenie płuc, w tym legionelozę. Badania ankietowe przeprowadzono w 9 zakładach mechanicznej obróbki szkła, wzięło w nich udział 131 osób. Badania mikrobiologiczne powietrza i wody wykonano w 1 wybranym zakładzie. W próbkach wody oznaczano obecność bakterii z rodzaju Legionella według PN-EN ISO 11731-2:2008 oraz ogólną liczbę mikroorganizmów według PN-EN ISO 6222:2004. Badania ogólnej liczby pleśni i grzybów w powietrzu prowadzono metodą zderzeniową. Wyniki: Występowanie ostrych dolegliwości ze strony układu oddechowego odnotowano u 28,2% osób, a dolegliwości przewlekłe u 29% osób. Najczęściej występującą dolegliwością był długotrwały kaszel, który zgłaszało 16% badanych. Rzadziej zgłaszana była duszność wysiłkowa (12,9%), świszczący oddech (12,2%) oraz ból w klatce piersiowej (10,7%). Stwierdzono zwiększone ryzyko kaszlu oraz zespołu ostrych objawów, które mogą sugerować zapalenie płuc w grupie osób wykonujących pracę w odległości do 20 m od źródła aerozolu wodno-powietrznego, w porównaniu z pozostałymi pracownikami. Badania mikrobiologiczne wody technologicznej wykazały obecność bakterii Legionella pneumophila w liczbie przekraczającej 1000 jtk/100 ml. Jednocześnie odnotowano wysoką liczbę bakterii i grzybów w powietrzu (> 1000 jtk/m³), których źródłem prawdopodobnie była woda technologiczna. Wnioski: Uzyskane dane ankietowe oraz badania pilotażowe skażenia mikrobiologicznego wody i powietrza na stanowiskach pracy wskazują na istnienie realnego zagrożenia zdrowia pracowników narażonych na wdychanie skażonego aerozolu wodnego. Med. Pr. 2013;64(1):47–55
EN
Background: The aim of the study was to confirm the fact that technological water is a significant carrier of Legionella, a potential serious threat to the health of operators of mechanical devices generating contaminated water aerosol. Material and Methods: Microbiological analyses of water and indoor air were conducted in 8 different production facilities involved in mechanical processing of glass. The study covered 81 samples of water collected from technical water systems. Isolation of Legionella and the determination of total number of microorganisms were processed according to PN-EN ISO 11731-2:2008E and PN-EN ISO 6222:2004P, respectively. Air samples were collected using air samplers and total numbers of bacteria and fungi were determined. Results: The studies of process water, indicated the presence of Legionella in 27.2% of collected samples. These bacteria were present in both closed and open process water reservoirs at 10 cfu/100 ml to 2.9×10⁴ cfu/100 ml. The count of other associated bacteria exceeded 10³ cfu/ml. All strains isolated from Legionella-positive samples were identified as L. pneumophila SG 2-14. In 5 of 8 studied production facilities an increased total number of aerial bacteria and fungi was observed in samples collected in close vicinity of aerosol source. Conclusions: To reduce the number of microorganisms in water it is required to introduce technological water quality monitoring and procedures for the cleaning and disinfecting of mechanical devices generating water aerosol. Med Pr 2014;65(3):325–334
PL
Wstęp: Celem badań była ocena stopnia zanieczyszczenia mikrobiologicznego wody i powietrza oraz ocena warunków sprzyjających rozwojowi mikroorganizmów, w tym pałeczek Legionella, w urządzeniach technologicznych. Materiał i metody: Badania mikrobiologiczne wody i powietrza przeprowadzono w 8 zakładach mechanicznej obróbki szkła. Łącznie pobrano 81 próbek wody z urządzeń wytwarzających aerozol wodny na stanowiskach pracy. W próbkach wody oznaczano pałeczki Legionella według PN-EN ISO 11731-2:2008E oraz ogólną liczbę mikroorganizmów według PN-EN ISO 6222:2004P. W próbkach powietrza, pobieranych metodą zderzeniową, oznaczano ogólną liczbę bakterii i grzybów. Wyniki: Badania wody technologicznej wykazały obecność pałeczek Legionella w 27,2% pobranych próbek wody. Bakterie te były obecne w próbkach wody pobranych zarówno z otwartych, jak i zamkniętych zbiorników wody technologicznej, a ich liczba wynosiła od 10 jtk/100 ml do 2,9×10⁴ jtk/100 ml. Liczba towarzyszących im innych bakterii przekraczała 10³ jtk/ml. We wszystkich próbkach Legionella-pozytywnych wyizolowane szczepy bakterii oznaczono, jako L. pneumophila sg 2-14. W 5 z 8 zakładów zaobserwowano wzrost ogólnej liczby bakterii i grzybów w powietrzu badanym w bezpośredniej bliskości źródła aerozolu. Wnioski: Zanieczyszczona mikrobiologicznie woda technologiczna, szczególnie bakteriami z rodzaju Legionella, stanowi realne zagrożenie dla zdrowia pracowników obsługujących urządzenia wytwarzające aerozol wodny. W celu obniżenia ryzyka infekcji wśród narażonych pracowników należy wprowadzić monitoring jakości wody technologicznej oraz procedury czyszczenia i dezynfekcji urządzeń generujących aerozol. Med. Pr. 2014;65(3):325–334
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.