Full-text resources of CEJSH and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

Results found: 4

first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  PM2.5
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Air pollution is a widespread environmental concern. Considerable epidemiological evidence indicates air pollution, particularly particulate matter (PM), as a major risk factor for cardiovascular diseases (CVD) in the developed countries. The main objective of our review is to assess the levels and sources of PM across the Middle East area and to search evidence for the relationship between PM exposure and CVD. An extensive review of the published literature pertaining to the subject (2000–2013) was conducted using PubMed, Medline and Google Scholar databases. We reveal that low utilization of public transport, ageing vehicle fleet and the increasing number of personal cars in the developing countries all contribute to the traffic congestion and aggravate the pollution problem. The annual average values of PM pollutants in the Middle East region are much higher than the World Health Organization 2006 guidelines (PM2.5 = 10 μg/m³, PM10 = 20 μg/m³). We uncover evidence on the association between PM and CVD in 4 Middle East countries: Iran, Kingdom of Saudi Arabia, Qatar and the United Arab Emirates. The findings are in light of the international figures. Ambient PM pollution is considered a potential risk factor for platelet activation and atherosclerosis and has been found to be linked with an increased risk for mortality and hospital admissions due to CVD. This review highlights the importance of developing a strategy to improve air quality and reduce outdoor air pollution in the developing countries, particularly in the Middle East. Future studies should weigh the potential impact of PM on the overall burden of cardiac diseases.
EN
Objectives: Secondhand smoke (SHS) is a defined occupational hazard. The association though between SHS exposure in semi-open air venues and tobacco specific carcinogen uptake is an area of debate. Material and Methods: A cross sectional survey of 49 semi-open air cafes in Athens, Greece was performed during the summer of 2008, prior to the adoption of the national smoke free legislation. All venues had at least 1 entire wall open to allow for free air exchange. Indoor concentrations of particulate matter smaller than 2.5 microns ($\text{PM}_\text{2.5}$) attributable to SHS were assessed during a work shift, while 1 non-smoking employee responsible for indoor and outdoor table service from each venue provided a post work shift urine sample for analysis of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL). Results: Post work shift NNAL concentrations were correlated with work shift $\text{PM}_\text{2.5}$ concentrations attributable to SHS (r = 0.376, p = 0.0076). Urinary NNAL concentrations among employees increased by 9.5%, per 10 μg/m³ increase in $\text{PM}_\text{2.5}$ concentrations attributable to SHS after controlling for the time of day and day of week. Conclusions: These results indicate that the commonly proposed practice of maintaining open sliding walls as a means of free air exchange does not lead to the elimination of employee exposure to tobacco specific carcinogens attributable to workplace SHS.
PL
Kraków należy do najbardziej zanieczyszczonych miast w Polsce. Szczególnie niebezpieczny dla zdrowia jest pył o frakcji 2,5 μm (PM2,5). Największa jego koncentracja w powietrzu występuje w półroczu chłodnym, szczególnie duża jest w lutym i grudniu. Najwyższe stężenia pyłu PM2,5 odnotowano na obszarze o gęstej zabudowie w centrum Krakowa, a w przebiegu dobowym – w godzinach wieczornych oraz nieco mniejsze w godzinach porannych, podczas szczytu komunikacyjnego. W półroczu chłodnym najwyższe stężenie PM2,5 stwierdzono podczas napływu mas powietrza z kierunku południowo- zachodniego i południowego, natomiast w półroczu ciepłym – z południowo-wschodniego i południowego. Wraz ze wzrostem prędkości wiatru stężenie pyłu PM2,5 wyraźnie się zmniejszało we wszystkich analizowanych punktach pomiarowych.
EN
Krakow is one of the most polluted cities in Poland. The dust fraction of 2.5 μm (PM2.5) has a significant impact on human health. The greatest concentration of PM2.5 was found for the cold half year (especially in February and December) and in the most densely built-up area of the city center. The worst air quality occurs in the evening and morning (peak traffic) hours. In the cold half year the highest concentration of PM2.5 was observed for the south-western and southern air masses advection, while in the warm half year for the south eastern and southern advection. The increase in wind speed is followed by a considerable decrease of the concentration of PM2.5 in all monitoring sites.
EN
The article discusses the conditions, benefits and limitations of building a nuclear power plant in Poland. Considerations in this regard were based on the SWOT analysis. The most serious challenges accompanying this kind of investment project in the energy sector were presented in more detail. They have been preceded by from the performed statistical analysis of the data the sources of PM10 and PM2.5 dust emission, which has led to the conclusion that burning coal by households is the main cause of emissions. They have negative consequences for the health and life of the population. In the situation where changes in the Polish energy system, related among others to the EU climate and energy policy, are necessary, it is vital to find alternative solutions. It is not easy. Renewable energy has a number of limitations (despite its many advantages), especially under adverse conditions such as few days of sunshine for photovoltaic technology. Therefore, this study aims to determine the legitimacy of building a nuclear power plant in Poland and verifies the research hypothesis that the lack of a stable energy policy is a serious barrier to the development of nuclear energy in Poland. Any decision on the changes in the energy system should be thoroughly analysed, taking into account not only the economic calculation, but also the time needed to make the necessary changes, social consequences (poor air quality in the case of coal burning) and environmental.
PL
Artykuł podejmuje zagadnienie uwarunkowań, korzyści i ograniczeń związanych z budową elektrowni jądrowej w Polsce. Rozważania w tym zakresie sporządzono na podstawie analizy SWOT. Zaprezentowano najpoważniejsze wyzwania towarzyszące temu przedsięwzięciu inwestycyjnemu w sektorze energetycznym. Przedstawione badania zostały poprzedzone wnioskami wypływającymi z analizy statystycznej danych dotyczących immisji pyłów PM10 i PM2,5. W jej efekcie ustalono, że spalanie węgla kamiennego przez gospodarstwa domowe jest główną przyczyną immisji, które negatywnie wpływają na zdrowie i życie ludzi. W sytuacji konieczności przeprowadzenia zmian w polskim systemie energetycznym, związanych m.in. z polityką klimatyczno-energetyczną Unii Europejskiej (UE), niezbędne jest znalezienie alternatywnych rozwiązań. Zadanie to nie jest jednak proste. Pozyskiwanie energii ze źródeł odnawialnych wiąże się z licznymi ograniczeniami – mimo wielu niezaprzeczalnych zalet – oraz z zawodnością tych źródeł, zwłaszcza w niesprzyjających warunkach (np. niewielka liczba dni słonecznych w przypadku technologii fotowoltaicznej). Dlatego też niniejsza praca stawia sobie za cel nie tylko określenie zasadności budowy elektrowni atomowej w Polsce, lecz także zweryfikowanie postawionej hipotezy badawczej, zgodnie z którą brak stabilnej polityki energetycznej stanowi poważną barierę rozwoju energetyki jądrowej w Polsce. Jakiekolwiek decyzje o zmianach w systemie energetycznym powinny uwzględniać rachunek ekonomiczny, czas potrzebny na ich przeprowadzenie, a także konsekwencje społeczne (niska jakość powietrza w przypadku spalania węgla) oraz środowiskowe.
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.