EN
Background: The aim of the study was to present the results of the interlaboratory comparisons for ring dosimeters and to confirm that the applied method is suitable for measuring the personal dose equivalent HP(0.07). In addition, calibration procedures used in dosimetric measurements in persons occupationally exposed to ionizing photon radiation X and γ were presented. Materials and Methods: Ring dosimeters made of flexible plastics with the diameter of approximately 20 mm, equipped with two thermoluminescence (TL) detectors type MTS-N, were the subject of interlaboratory comparisons. Irradiated detectors were red out using a new manual TLD's reader (FIMEL, France). All TLD exposures were done for validation of TLD readers and were performed using the reference X-ray and γ beams with the ISO rod phantom. The methodology of performed exposures corresponded with the methods applied by the European Radiation Dosimetry Group (EURADOS), the European organizer of interlaboratory comparisons. Results: The energy, dose and angular characteristics of the ring dosimeter allowed to elaborate the formula for estimating and verifying the personal dose equivalent HP(0.07). The test was performed to check and confirm the correctness of the estimated characteristics. The test results were satisfactory, and thus the readiness to implement TLD reader in the used method and to participate in interlaboratory comparisons was confirmed. Conclusions: According to the requirements of the Polish Centre for Accreditation, the laboratory was participating in the interlaboratory comparison organized by EURADOS in terms of the personal dose equivalent HP(0.07). The result of the comparison was satisfactory, therefore the correctness of the testing procedure was confirmed. Med Pr 2013;64(5):631–637
PL
Wstęp: Celem pracy było potwierdzenie, na podstawie wyników porównań międzylaboratoryjnych dla dozymetrów pierścionkowych, że stosowana metoda badawcza jest odpowiednia do pomiaru indywidualnego równoważnika dawki HP(0,07). Ponadto w pracy przedstawiono procedury kalibracyjne stosowane podczas walidacji metody badawczej przed wdrożeniem do rutynowych pomiarów związanych z oceną narażenia pracowników na działanie promieniowania X i γ. Materiał i metody: Przedmiotem porównań międzylaboratoryjnych były dozymetry pierścionkowe wykonane z elastycznego tworzywa o standardowej średnicy 20 mm i z umieszczonymi wewnątrz dwoma detektorami termoluminescencyjnymi (TL) typu MTS-N - po naeksponowaniu u organizatora porównań odczytywano je za pomocą nowego, manualnego czytnika detektorów TL (prod. FIMEL, Francja). Wszystkie ekspozycje dozymetrów, przeprowadzone dla celów walidacyjnych ww. czytnika, wykonano we wzorcowych wiązkach promieniowania X i γ z zastosowaniem fantomu prętowego ISO. Metodyka wykonanych ekspozycji była odpowiednia do potrzeb pracowni oraz zgodna z metodami stosowanymi przez Europejskę Grupę ds. Dozymetrii Promieniowania (European Radiation Dosimetry Group - EURADOS) - organizatora porównań międzylaboratoryjnych o europejskim zasięgu w zakresie dozymetrii indywidualnej. Wyniki: Wykonane charakterystyki - energetyczna, dawkowa i kątowa dozymetru pierścionkowego - umożliwiły opracowanie wzoru dotyczącego oszacowania indywidualnego równoważnika dawki HP(0,07) oraz poddania go testowi weryfikacyjnemu. Stwierdzono zadowalający wynik testu oceny wielkości HP(0,07) i tym samym potwierdzono gotowość wdrożenia czytnika termoluminescencyjnego do stosowanej metody badawczej oraz uczestniczenia w porównaniach międzylaboratoryjnych. Wnioski: Laboratorium - zgodnie z wymaganiami Polskiego Centrum Akredytacji - uczestniczyło w porównaniach międzylaboratoryjnych (organizowanych przez grupę EURADOS) w zakresie pomiaru dawki równoważnej na ręce promieniowania jonizującego X i γ. Wynik porównania był pozytywny, a jego przedmiotem były dozymetry pierścionkowe. Potwierdzono tym samym prawidłowość realizowanej procedury badawczej. Med. Pr. 2013;64(5):631–637
Medycyna Pracy
|
2018
|
vol. 69
|
issue 3
317-327
EN
Background A radiopharmaceutical is a combination of a non-radioactive compound with a radioactive isotope. Two isotopes: technetium- 99m ($ \text{}^\text{99m}\text{Tc} $) and fluorine-18 ($ \text{}^\text{18}\text{F} $) are worth mentioning on the rich list of isotopes which have found numerous medical applications. Their similarity is limited only to the diagnostic area of applicability. The type and the energy of emitted radiation, the half-life and, in particular, the production method demonstrate their diversity. The $ \text{}^\text{99m}\text{Tc} $ isotope is produced by a short-lived nuclide generator – molybdenum-99 ($ \text{}^\text{99}\text{Mo} $)/$ \text{}^\text{99m}\text{Tc} $, while $ \text{}^\text{18}\text{F} $ is resulting from nuclear reaction occurring in a cyclotron. A relatively simple and easy handling of the $ \text{}^\text{99}\text{Mo} $ \text{}^\text{99m}\text{Tc} $ generator, compared to the necessary use a cyclotron, seems to favor the principle of optimizing the radiological protection of personnel. The thesis on the effect of automation of both the $ \text{}^\text{18}\text{F} $ isotope production and the deoxyglucose labelling process on the optimization of radiological protection of workers compared to manual procedures during handling of radiopharmaceuticals labelled with $ \text{}^\text{99m}\text{Tc} $ need to be verified. Material and Methods Measurements of personal dose equivalent Hp(0.07) were made in 5 nuclear medicine departments and 2 radiopharmaceuticals production centers. High-sensitivity thermoluminescent detectors (LiF: Mg, Cu, P – MCP-N) were used to determine the doses. Results Among the activities performed by employees of both $ \text{}^\text{18}\text{F} $-fluorodeoxyglucose ($ \text{}^\text{18}\text{F} $-FDG) production centers and nuclear medicine departments, the manual quality control procedures and labelling of radiopharmaceuticals with $ \text{}^\text{99m}\text{Tc} $ isotope manifest the greatest contribution to the recorded Hp(0.07). Conclusions The simplicity of obtaining the $ \text{}^\text{99m}\text{Tc} $ isotope as well as the complex, but fully automated production process of the $ \text{}^\text{18}\text{F} $-FDG radiopharmaceutical optimize the radiation protection of workers, excluding manual procedures labelling with $ \text{}^\text{99m}\text{Tc} $ or quality control of $ \text{}^\text{18}\text{F} $-FDG. Med Pr 2018;69(3):317–327
PL
Wstęp Radiofarmaceutyk to produkt będący połączeniem niepromieniotwórczego związku chemicznego i znacznika izotopowego. Na bogatej liście izotopów mających zastosowane w medycynie na uwagę zasługują 2 – technet-99m ($ \text{}^\text{99m}\text{Tc} $) i fluor-18 ($ \text{}^\text{18}\text{F} $). Ich podobieństwo ogranicza się jedynie do diagnostycznego obszaru stosowalności, a dzieli je m.in. rodzaj i energia emitowanego promieniowania, czas połowicznego rozpadu czy w szczególności sposób produkcji. Izotop $ \text{}^\text{99m}\text{Tc} $ uzyskuje się dzięki generatorom nuklidów krótkożyciowych – molibdenu-99 ($ \text{}^\text{99}\text{Mo} $)/$ \text{}^\text{99m}\text{Tc} $, a $ \text{}^\text{18}\text{F} $ powstaje w reakcji jądrowej zachodzącej w cyklotronie. Stosunkowo łatwy sposób obsługi generatora $ \text{}^\text{99}\text{Mo} $/$ \text{}^\text{99m}\text{Tc} $ w porównaniu z koniecznością wykorzystania cyklotronu wydaje się sprzyjać zasadzie optymalizacji ochrony radiologicznej personelu. Weryfikacja tezy dotyczącej wpływu automatyki zarówno produkcji znacznika $ \text{}^\text{18}\text{F} $, jak i procesu znakowania deoksyglukozy na zoptymalizowanie ochrony radiologicznej pracowników w porównaniu z manualnymi procedurami wykonywanymi podczas znakowania preparatów izotopem $ \text{}^\text{99m}\text{Tc} $. Materiał i metody Dawki równoważne Hp(0,07) zmierzono w 5 zakładach medycyny nuklearnej i 2 ośrodkach produkujących znaczniki pozytonowe, w szczególności $ \text{}^\text{18}\text{F} $. W pomiarach dozymetrycznych wykorzystano wysokoczułe detektory termoluminescencyjne wykonane z fluorku litu (LiF: Mg, Cu, P – MCP-N). Wyniki Wśród czynności wykonywanych przez pracowników zarówno placówek produkujących $ \text{}^\text{18}\text{F} $-fluorodeoksyglukozę ($ \text{}^\text{18}\text{F} $-FDG), jak i zakładów medycyny nuklearnej manualne procedury kontroli jakości oraz znakowanie preparatu mają największy wkład do zarejestrowanych wartości dawek Hp(0,07). Wnioski Prosty sposób uzyskania znacznika $ \text{}^\text{99m}\text{Tc} $ podobnie jak złożony (choć w pełni zautomatyzowany) proces produkcji $ \text{}^\text{18}\text{F} $-FDG optymalizuje ochronę radiologiczną personelu z wyłączeniem manualnych procesów znakowania związków chemicznych $ \text{}^\text{99m}\text{Tc} $ bądź kontroli jakości $ \text{}^\text{18}\text{F} $-FDG. Med. Pr. 2018;69(3):317–327