Full-text resources of CEJSH and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

Results found: 2

first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  drobny pył PM2,5
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Background An important issue in the assessment of health risks related to air pollution with fine dust is the measurement of individual exposure. Such possibilities are provided by relatively easy to use optical monitors. The aim of the presented work was to assess the possibility of using the AM520 optical monitor to measure individual human exposure to PM2.5 and PM10 indoors by determining the calibration factor and assessing the compliance of the measurement with the reference method. Material and Methods As part of the research, indoor concentrations of PM2.5 and PM10 and were measured (3 locations in the Gliwice Poviat, March−May 2017) with the use of the SidePak Personal Aerosol Monitor AM520, as well as the reference LVS3D device by means of the gravimetric method. The value of the calibration coefficient for the optical monitor was determined, and the consistency of measurements performed with both methods was assessed. Results The photometric calibration factor ranged 0.33−0.40 and was concurrent with the 0.38 value recommended by the manufacturer. The determination coefficient for the correlation between the measurement results obtained with the optical and gravimetric methods was very high (R2 = 0.91). Conclusions The presented results are promising and allow for the conclusion that the AM520 optical monitor can be used to assess individual exposure to PM2.5 and PM10 indoors. Med Pr. 2019;70(2):213–20
PL
Wstęp Istotną kwestią w ocenie ryzyka zdrowotnego jest pomiar indywidualnego narażenia, także dla zanieczyszczenia powietrza atmosferycznego drobnym pyłem. Takie możliwości dają stosunkowo proste w obsłudze mierniki optyczne. Celem pracy była ocena możliwości wykorzystywania optycznego miernika AM520 do pomiaru indywidualnego narażenia ludzi na drobny pył PM2,5 i PM10, zawarty w pomieszczeniach zamkniętych, poprzez ustalenie współczynnika kalibracji i ocenę zgodności pomiaru z metodą referencyjną. Materiał i metody W ramach badań wykonano pomiary stężeń pyłu PM2,5 i PM10 w pomieszczeniach (3 lokalizacje w powiecie gliwickim, marzec−maj 2017 r.) z wykorzystaniem aspiratora osobistego SidePak model AM520, a także z użyciem urządzenia referencyjnego LVS3D metodą grawimetryczną. Ustalono wartość współczynnika kalibracji dla optycznego miernika i zgodność pomiarów wykonanych obydwiema metodami. Wyniki Zakres wartości fotometrycznego współczynnika kalibracji kształtował się na poziomie 0,33–0,40 i był zbieżny z wartością 0,38 zalecaną przez producenta. Współczynnik determinacji dla zależności wyników uzyskanych metodą optyczną oraz grawimetryczną był bardzo wysoki i wynosił R2 = 0,91. Wnioski Prezentowane wyniki są obiecujące i pozwalają stwierdzić, że optyczny miernik AM520 może być wykorzystywany do oceny indywidualnego narażenia na drobne pyły PM2,5 i PM10 w pomieszczeniach zamkniętych. Med. Pr. 2019;70(2):213–220
Medycyna Pracy
|
2018
|
vol. 69
|
issue 5
523-530
EN
Background Recurring winter smog episodes, recently observed in Poland, have inspired the researches to assess the epidemiological situation concerning the registered exacerbations of respiratory diseases related to worsening of the ambient air quality. Material and Methods The model comprising the ecological study results and secondary epidemiological data on registered outpatient visits and hospitalizations in the Silesian voivodeship was used. We assessed the effect of smog observed in January 2017 on the number of acute respiratory disorders registered in that month. Aerosanitary situation was obtained from the Provincial Inspectorate for Environmental Protection in Katowice database. Results It was documented that the increase in $\text{PM}_\text{2.5}$ concentration (with simultaneously observed unfavorable meteorological parameters) was related to a higher number of acute respiratory disorders registered daily. Moreover, the increase in the number of outpatient visits due to asthma exacerbation or bronchitis was observed on the first day of episode, and hospitalizations took place with delay of 1–2 days. Conclusions The preliminary results indicate the relationship between worsening of ambient air quality during the winter smog and the increase in daily number of registered outpatient visits and hospitalizations due to acute respiratory diseases. Med Pr 2018;69(5):523–530
PL
Wstęp Obserwowane w ostatnich latach w Polsce cyklicznie powtarzające się – w każdym sezonie zimowym – epizody smogowe stały się inspiracją do badań nad sytuacją epidemiologiczną zaostrzeń chorób układu oddechowego zarejestrowanych w odpowiedzi na pogorszenie jakości powietrza atmosferycznego. Materiał i metody Na podstawie modelu badania ekologicznego i wtórnych danych epidemiologicznych dotyczących rejestrowanych porad ambulatoryjnych oraz hospitalizacji w województwie śląskim oceniono wpływ smogu ze stycznia 2017 r. na liczbę udzielonych w tym miesiącu świadczeń medycznych z powodu ostrych incydentów oddechowych. Informacje o sytuacji aerosanitarnej w badanym okresie pochodzą z bazy danych Wojewódzkiego Inspektoratu Ochrony Środowiska w Katowicach. Wyniki Zaobserwowano wpływ wzrostu stężeń pyłu $\text{PM}_\text{2,5}$ (przy jednocześnie notowanych niekorzystnych parametrach meteorologicznych) na zwiększenie dziennej liczby udzielanych świadczeń medycznych z powodu ostrych incydentów oddechowych. Wzrost liczby porad z powodu zaostrzenia astmy oraz zapalenia oskrzeli zanotowano już pierwszego dnia epizodu. Liczba osób hospitalizowanych zwiększyła się natomiast dopiero po 2 dniach. Wnioski Uzyskane wyniki wstępnych badań wskazują na związek między pogorszeniem jakości powietrza w trakcie zimowego epizodu smogowego a wzrostem liczby rejestrowanych porad ambulatoryjnych i hospitalizacji z powodu ostrych chorób układu oddechowego. Med. Pr. 2018;69(5):523–530
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.