Results found: 2

first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  polycyclic aromatic hydrocarbons
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Objectives: The aim of the study was to characterize the PAH exposure level based on 1-hydroxypyrene (1-HP) in urine of Polish pregnant women and to assess the relationship between PAH and factors such as smoking, environmental tobacco smoke exposure, place of residence, heating and cooking method. Materials and Methods: The study population included in this analysis consisted of 449 pregnant women who had been the subjects of the prospective Polish Mother and Child Cohort study performed in 8 regions of Poland. The women were interviewed three times during pregnancy (once in each trimester). 1–HP concentration in urine was chosen as the biomarker of exposure to PAH. The urine sample was analysed using high performance liquid chromatography (HPLC). The active and passive smoking exposure was verified by saliva cotinine, analysed by high performance liquid chromatography coupled with tandem mass spectrometry (LC-MSMS) and isotope dilution method. Results: 1-HP concentration in urine ranged from 0.02 to 10.2 μg/g creatinine with the geometric mean (GM) 0.4 μg/g creatinine. The significantly higher concentration of urinary 1-HP in pregnant women was observed for summer collection (GM ratio: 1.1; p = 0.01), among smokers (GM ratio: 1.7; p < 0.001) and for the women living in big cities (GM ratio: 1.3; p = 0.001). Conclusions: The significantly higher concentration of urinary 1-HP in pregnant women was observed for summer collection, among smokers and those living in big cities.
EN
Background: This article presents the study of polycyclic aromatic hydrocarbons (PAHs) adsorbed on fine particles emitted during the simulated operation of office printers and copiers. Material and Methods: In the study three types of printers, and four types of office copiers were used. Measurements were carried out in a closed measuring chamber. Air samples (fractions of particulate matter, PM 10 and PM 2.5) were collected on Teflon filters. The analysis of PAHs was carried out according HPLC/FL. Results: The results of qualitative analysis of filters from PM 2.5 and PM 10 type samplers indicated the presence of the majority (10–14) of PAH congeners. The highest concentration of total PAHs was determined in the PM 10 fraction in the air during the operation of a copier, and amounted to 36.52 μg×g -¹. The total content of PAHs as determined in the fraction of fine particulates, size of < 2.5 μm, accounts for 48–84% of the PAH content in the < 10 μm fraction for printers and 63–89% for copiers. During the operation of both printers and copiers, benzo(a)pirene (BaP) was identified in both fractions, PM 2.5 and PM 10. The maximum concentration of BaP in the fraction of < 10 μm particles emitted by a printer amounted to 3.29±0.2 μg×g -¹. Conclusions: The studies showed that the composition of emitted substances and fine particles depends on the type of equipment and technology used. Fine particles emitted to the environment and organic compounds, including PAHs adsorbed on them may pose a threat to people working in such an environment. Med Pr 2014;65(6):733–741
PL
Wstęp: W artykule przedstawiono wyniki badań wielopierścieniowych węglowodorów aromatycznych (WWA) zaadsorbowanych na cząstkach drobnych emitowanych podczas pracy urządzeń powielających. Materiał i metody: Do badań wytypowano 3 rodzaje drukarek i 4 rodzaje kserokopiarek. Pomiary prowadzono w zamkniętej komorze pomiarowej, którą dodatkowo umieszczono pod wyciągiem laboratoryjnym. W komorze umieszczano urządzenia drukujące lub kopiujące oraz aspiratory połączone z próbnikami. Próbki powietrza pobierano na filtry teflonowe, umieszczone w próbnikach do pobierania frakcji pyłu drobnego (particulate matter – PM) PM 10 i PM 2,5. Analizę WWA osadzonych na cząstkach stałych, emitowanych z urządzeń powielających, prowadzono metodą wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (high pressure liquid chromatography with fluorescence detection – HPLC/FL). Wyniki: Wyniki analizy jakościowej wykazały obecność większości 10–14 wielopierścieniowych węglowodorów aromatycznych. Największe stężenie sumy WWA (36,52 μg×g -¹) oznaczono we frakcji PM 10 w powietrzu podczas pracy kserokopiarki. Sumaryczną zawartość WWA oznaczona we frakcji cząstek drobnych < 2,5 μm stanowią 48–84% zawartości WWA we frakcji < 10 μm w przypadku drukarek i 63–89% w przypadku kserokopiarek. Zarówno podczas pracy urządzeń drukujących, jak i powielających w obydwu frakcjach PM 2,5 oraz PM 10 zidentyfikowano benzo(a)piren (BaP). Maksymalne stężenie BaP we frakcji cząstek < 10 μm emitowanych z drukarki wynosiło 3,29±0,2 μg×g -¹. Wnioski: Badania wykazały, że stężenie emitowanych substancji zaadsorbowanych na PM 10 i PM 2,5 oraz stężenie tych cząstek w powietrzu nie jest stałe i zależy od rodzaju stosowanego urządzenia, rodzaju tonera i szybkości powielania. Emitowane do środowiska pracy cząstki drobne oraz osadzone na nich WWA mogą stanowić zagrożenie dla osób pracujących w ich otoczeniu. Med. Pr. 2014;65(6):733–741
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.