EN
The applications of X-rays and the principles of X-ray fluorescence analysis have been described. The following X-ray techniques are presented: EDXRF, WDXRF, TXRF, SXRF, PIXE, SEM-EDS and WDS, EMPA. Several topics are discussed in detail: sources of excitation including excitation with charged particles, detection of characteristic radiation, measurement geometry, spectrometer configurations including also portable instruments, examination of microregions. The statistical evaluation of the measurement results is comprehensively treated. A particular attention is given to the application of XRF in examination of the art objects and the archaeological findings. The main advantages o f XRF are a non-destructive measurement, possibility to measure a very small area and a portability of some instruments. Some limitations of this method are also mentioned. The examples of the historical glass examination from the own research as well as from the literature are presented.
Medycyna Pracy
|
2021
|
vol. 72
|
issue 1
49-59
EN
Ionizing radiation as a scientific achievement provides a variety of advantages, e.g., in the medical field. However, it also causes a risk of some illnesses, e.g., cataract or cancer. This results in the need to measure radiation doses and to reduce the unnecessary risk. There are 3 main methods of dose reduction, i.e., shortening the time of exposure, working as far as possible from the X-ray source, and using radioprotective shields. Together with the development of science and technology, dose reduction methods and radioprotection methods have also evolved. Besides improved shielding, the ergonomics is also more advanced, e.g., the zero-gravity shielding or light, and non-lead aprons. What is more, the awareness of using radiological protection and conducting the surgery in the safest way for both the staff and the patient is growing up. The goal of this article is to discuss the newest methods of radiation protection against the background of 3 main protection principles.
PL
Odkrycie promieniowania jonizującego przyniosło wiele korzyści również w medycynie. Związane z nim ryzyko wywoływania chorób, takich jak nowotwory popromienne czy zaćma, skutkuje koniecznością monitorowania narażenia osób pracujących w ekspozycji na promieniowanie jonizujące za pomocą dozymetrii indywidualnej lub optymalizacji procedur medycznych. Istnieją 3 główne sposoby optymalizacji procedur medycznych – redukcja czasu, zwiększenie odległości oraz stosowanie osłon osobistych i stałych. Wraz z rozwojem nauki i techniki ewoluują sposoby zmniejszania dawki. Poza lepszą osłonnością wzrasta także ergonomia, jak w przypadku osłony Zero-Gravity i lekkich fartuchów bezołowiowych. Rośnie także świadomość konieczności stosowania osłon i prowadzenia zabiegu tak, aby zmniejszyć narażenie zarówno personelu, jak i pacjenta. Celem artykułu jest przedstawienie nowych metod ochrony przed promieniowaniem jonizującym w kontekście powyższych 3 pryncypiów ochrony radiologicznej.
EN
Background: Lead aprons, as a type of individual radiological shields, are designed to protect the body against the negative effects of ionizing radiation. In order for the individual shields to fulfill their task, the weakening of the X-ray beam should be as high as possible. Previous reports have indicated the possibility of significant defects even among newly purchased aprons. The aim of the study was to analyze the influence of storage conditions and usage time on the permeability of lead aprons. Material and Methods: The analysis covered 11 lead aprons used by the staff and patients of the Department of Radiodiagnostics and Interventional Radiology of the Central Clinical Hospital in Katowice, Poland. The dependent variable was the average pixel value, and the grouping variables included the storage method, age and thickness of the apron, and the type of its user. Results: Statistically significant differences were found between the weakening value of the X-ray beam of individual aprons, and their storage conditions and age. Conclusions: Aprons stored in a hanging position show a greater degree of weakening of the X-ray beam, and thus a higher degree of worker protection, compared to aprons stored otherwise. The age of the apron affects its protective properties.
PL
Wstęp: Fartuchy ołowiane – jako jeden z typów indywidualnych osłon radiologicznych – mają za zadanie chronić ciało przed szkodliwym działaniem promieniowania jonizującego. Aby osłony indywidualne spełniały swoje zadanie, wartość osłabienia wiązki promieniowania rentgenowskiego (RTG) powinna być jak najwyższa. Dotychczasowe doniesienia wskazują na możliwość występowania istotnych defektów nawet w nowo zakupionych fartuchach. Celem tej pracy była analiza wpływu warunków przechowywania i czasu użytkowania fartuchów ołowianych na wartość osłabienia przez nie wiązki promieniowania RTG. Materiał i metody: Analizie poddano 11 fartuchów ołowianych wykorzystywanych przez personel i pacjentów Zakładu Radiodiagnostyki i Radiologii Zabiegowej Uniwersyteckiego Centrum Klinicznego im. prof. K. Gibińskiego w Katowicach. Zmienną zależną była średnia wartość piksela, a za zmienne grupujące przyjęto sposób przechowywania fartucha, jego wiek i grubość oraz typ jego użytkownika. Wyniki: Wykazano istotne statystycznie różnice pomiędzy wartością osłabienia wiązki promieniowania RTG poszczególnych fartuchów a ich warunkami przechowywania i wiekiem. Wnioski: Fartuchy przechowywane w pozycji wiszącej wykazują większy stopień osłabienia wiązki promieniowania RTG, a tym samym lepszą ochronę pracownika, w stosunku do fartuchów składowanych w inny sposób. Wiek fartucha wpływa na jego właściwości ochronne.
EN
Background The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes. Material and Methods Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films. Results The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs. Conclusions The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491–496
PL
Wstęp Stosowanie w procedurach stomatologicznych promieniowania rentgenowskiego (rtg.) powoduje narażenie pacjenta na promieniowanie jonizujące. Wielkość tego narażenia zależy przede wszystkim od parametrów stosowanych przy prześwietleniu zęba. Celem badań było określenie wielkości dawek, na jakie narażeni są pacjenci, oraz ocena stanu technicznego aparatów rtg. Materiał i metody Badaniami ankietowymi objęto 1700 gabinetów stomatologicznych. Ankiety odesłało 740 jednostek. Pomiary bezpośrednie wykonano w 100 gabinetach. Pomiary wykonano za pomocą detektorów termoluminescencyjnych i klisz rtg. Wyniki W przeprowadzonych badaniach stwierdzono, że najczęściej stosowany czas ekspozycji wynosi 0,22±0,16 s. Średnia dawka wejściowa dla parametrów najczęściej stosowanych przez stomatologów to 1,7±1,4 mGy. Średnia wydajność lampy rtg. oszacowana na podstawie wykonanych ekspozycji wynosi 46,5±23,7 μGy/mAs. Wnioski Jak wynika z przeprowadzonych badań, znakomita większość aparatów rtg. punktowych spełnia wymagania określone w przepisach. Med. Pr. 2017;68(4):491–496