Background Some cardiac implantable electronic device (CIED) implantation procedures require the use of X-rays, which is reflected by such parameters as total fluoroscopy time (TFT) and dose-area product (DAP – defined as the absorbed dose multiplied by the area irradiated). Material and Methods This retrospective study evaluated 522 CIED implantation (424 de novo and 98 device upgrade and new lead placement) procedures in 176 women and 346 men (mean age 75±11 years) over the period 2012–2015. The recorded procedure-related parameters TFT and DAP were evaluated in the subgroups specified below. The group of 424 de novo procedures included 203 pacemaker (PM) and 171 implantable cardioverter-defibrillator (ICD) implantation procedures, separately stratified by single-chamber and dual-chamber systems. Another subgroup of de novo procedures involved 50 cardiac resynchronization therapy (CRT) devices. The evaluated parameters in the group of 98 upgrade procedures were compared between 2 subgroups: CRT only and combined PM and ICD implantation procedures. Results We observed differences in TFT and DAP values between procedure types, with PM-related procedures showing the lowest, ICD – intermediate (with values for single-chamber considerably lower than those for dual-chamber systems) and CRT implantation procedures – highest X-ray exposure. Upgrades to CRT were associated with 4 times higher TFT and DAP values in comparison to those during other upgrade procedures. Cardiac resynchronization therapy de novo implantation procedures and upgrades to CRT showed similar mean values of these evaluated parameters. Conclusions Total fluoroscopy time and DAP values correlated progressively with CIED implantation procedure complexity, with CRT-related procedures showing the highest values of both parameters. Med Pr 2017;68(3):363–374
PL
Wstęp Realizacja części procedur CIED (cardiac implantable electronic device – stałej elektroterapii serca) wymaga zastosowania promieniowania rentgenowskiego (rtg.), co znajduje odzwierciedlenie w czasie ekspozycji TFTs (total fluoroscopy times – łączny czas naświetlania) oraz wielkości dawki promieniowania rtg. wyemitowanej na skórę pacjenta (dose area product – DAP). Materiał i metody Badaniem retrospektywnym dotyczącym lat 2012–2015 objęto 522 procedury CIED (u 176 kobiet i 346 mężczyzn, średnia wieku: 75±11 lat), z których 424 były zabiegami pierwszorazowymi (de novo), a 98 powtórnymi (upgrade), wymagającymi wprowadzenia nowej elektrody i zmiany urządzenia. Zarejestrowane po ich realizacji parametry TFTs i DAP odniesiono do wymienionych poniżej grup. Grupę 424 zabiegów de novo tworzyły: 203 implantacje stymulatorów (pacemaker – PM), 171 implantacji kardiowerterów-defibrylatorów (implantable cardiowerter-defibrylator – ICD), w których obrębie niezależnie wyodrębniono układy 1- i 2-jamowe, oraz 50 implantacji układów resynchronizujących (cardiac resynchronization therapy – CRT). W przypadku grupy 98 procedur upgrade porównano parametry między 2 podgrupami zabiegów – tylko do CRT oraz tylko w obrębie PM i ICD. Wyniki Najniższe wartości TFTs i DAP towarzyszyły implantacjom PM, pośrednie – ICD, z wyraźnym wzrostem w przypadku układów 2-jamowych w stosunku do 1-jamowych. Najwyższe wartości TFTs i DAP cechowały zabiegi CRT. Zabiegom upgrade do CRT towarzyszyły 4-krotnie większe wartości TFTs i DAP w porównaniu z upgrade niezwiązanym z CRT. W przypadku zabiegów CRT de novo i CRT upgrade średnie wartości mierzonych parametrów były zbliżone. Wnioski Czas ekspozycji i wielkość DAP pozostawały dodatnio związane z zaawansowaniem procedury CIED, przy czym zabiegi z zakresu CRT wyróżniały się ich największymi wartościami. Med. Pr. 2017;68(3):363–374
EN
Background One of the numerous sub-areas of interventional radiology is the use of X-rays in gastroenterology. X-ray fluoroscopy is applied in therapeutic procedures, including endoscopic retrograde cholangiopancreatography (ERCP) that is frequently performed. The ERCP procedure is aimed at imaging the pancreatic duct and biliary tracts. Material and Methods In this paper radiation risk to the gastrenterologist performing ERCP procedures was investigated. The procedures were performed by a single gastroenterologist in the ERCP Laboratory, University Clinical Hospital Military Memorial Medical Academy – Central Veterans’ Hospital in Łódź, Poland. The study comprised 2 series of measurements, one taken during the procedures with continuous fluoroscopy mode, the other during procedures with fluoroscopy in pulsed mode at a frequency of 3 pulses/s. Exposure parameters, anatomical data of patient and dose equivalents for the eyes, skin of the hand and the effective dose for whole body of the gastroenterologist were recorded during each procedure. Results The collected data cover 70 ERCP procedures – 40 procedures were controlled by continuous fluoroscopy and 30 by pulsed fluoroscopy. The results reveal that pulsed fluoroscopy makes it possible to reduce doses received by the gastroeneterologist from 45% to 60% compared to continuous fluoroscopy. Conclusions Endoscopic retrograde cholangiopancreatography procedures can cause radiation risk to the gastroenterologist performing them. The use of continuous fluoroscopy can result in achieving an equivalent dose to eye lens nearly 20 mSv per year, i.e., the decreased annual limit recommended by the International Commission on Radiological Protection (ICRP). Med Pr 2017;68(6):735–741
PL
Wstęp Wykorzystanie promieniowania rentgenowskiego (rtg.) w gastroenterologii stanowi jeden z licznych podobszarów radiologii interwencyjnej. W gastroenterologii fluoroskopia rtg. jest używana w procedurach terapeutycznych, z których częsta jest endoskopowa cholangiopankreatografia wsteczna (ECPW). Procedura ECPW pokazuje radiologiczny obraz dróg żółciowych i przewodu trzustkowego. Materiał i metody W ramach niniejszej pracy przeprowadzono ocenę narażenia na promieniowanie rtg. gastroenterologa wykonującego zabiegi ECPW pod kontrolą fluoroskopii. Badania przeprowadzono w Pracowni ECPW Uniwersyteckiego Szpitala Klinicznego im. Wojskowej Akademii Medycznej – Centralnego Szpitala Weteranów w Łodzi, gdzie gastroenterolog wykonuje je samodzielnie. Realizując cel pracy, wykonano 2 serie pomiarów – pierwsza składała się z zabiegów wykonanych w trybie fluoroskopii ciągłej, druga – z zabiegów, które wykonano w trybie fluoroskopii impulsowej (o częstotliwości 3 pulsy/s). Podczas każdej procedury rejestrowano parametry ekspozycji, dane anatomiczne pacjenta, a także otrzymywane przez gastroenterologa równoważniki dawek dla soczewek oczu i skóry dłoni oraz dawkę efektywną dla całego ciała. Wyniki Zebrano dane dotyczące ogółem 70 zabiegów ECPW, w tym 40 zabiegów wykonanych w trybie fluoroskopii ciągłej i 30 – w trybie fluoroskopii impulsowej. Na podstawie uzyskanych wyników stwierdzono, że gastroenterolog wykonujący procedury ECPW w trybie fluoroskopii impulsowej otrzymuje dawki promieniowania niższe o 45–60% niż podczas pracy w trybie fluoroskopii ciągłej. Wnioski Procedury ECPW mogą być źródłem narażenia na promieniowanie rtg. dla wykonującego je gastroenterologa. Używanie trybu fluoroskopii ciągłej może pozwolić na osiągnięcie obniżonej wartości rocznego limitu dawki równoważnej dla soczewek oczu (tj. 20 mSv), rekomendowanej przez Międzynarodową Komisję Ochrony Radiologicznej (International Commission on Radiological Protection – ICRP). Med. Pr. 2017;68(6):735–741