Full-text resources of CEJSH and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

Results found: 3

first rewind previous Page / 1 next fast forward last

Search results

help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Introduction European Union Directive 2013/35/UE provides for the implementation of EU regulations into national legislation. Our aim is to assess actual health hazards from radiofrequency electromagnetic field (RF EMF) (range: 100 kHz – 300 GHz) and indicate workplaces with the highest risk to employee health. Material and Methods Data from measurements of RF EMF performed by the Laboratory of Electromagnetic Hazards in Nofer Institute of Occupational Medicine (Łódź, Poland) were analyzed. The analysis covered the results of electric field intensity (E) for over 450 selected items. The ranges of protection zones and the extent to which maximum admissible intensity (MAI) values were also analyzed. The determinations and measurements of EMF in the work environment met the requirements of Polish Standard, while Polish regulations on the MAI values were used as the criterion for the assessment of the exposure. Results The highest values of E field intensity at workplaces were measured for: electrosurgery, to 400 V/m, and short-wave diathermy units, to 220 V/m, dielectric welders to 240 V/m, within the FM radio antenna systems, to 180 V/m. The widest protection zones were noted for prototype research instruments, short-wave diathermy units, and dielectric welders. The most excessive (up to 12-fold MAI) values were recorded for dielectric welders, short-wave diathermy units (up to 11-fold) and microwave diathermy units (up to 8-fold). Conclusions Our results have confirmed the high RF EMF values for physiotherapists, operators of dielectric welders, and mast maintenance workers in radio communication facilities (especially radio and TV broadcasting stations). Med Pr 2015;66(2):199–212
PL
Wstęp Dyrektywa 2013/35/UE nałożyła obowiązek implementacji przepisów UE do prawa krajowego. Celem pracy jest ocena aktualnego stanu zagrożeń wynikających ze stosowania urządzeń wytwarzających PEM RF w zakresie od 100 kHz do 300 GHz oraz wskazanie urządzeń i miejsc pracy o najwyższym ryzyku narażenia zdrowia pracowników. Materiał i metody Materiał stanowiły dane pochodzące z badań i pomiarów PEM RF realizowanych w Pracowni Zagrożeń Elektromagnetycznych Instytutu Medycyny Pracy im. prof. J. Nofera w Łodzi. Szczegółowej analizie poddano wyniki pomiarów natężenia pola elektrycznego (E) dla ponad 450 wybranych urządzeń, reprezentatywnych dla działów gospodarki, w których najczęściej są stosowane. Analizowano również zasięg występowania stref ochronnych i krotność przekroczenia najwyższego dopuszczalnego natężenia (NDN). Pomiary i badania PEM w środowisku pracy były zgodne z Polską Normą, a kryterium oceny ekspozycji stanowiły polskie przepisy o NDN. Wyniki Najwyższe zmierzone wartości natężenia pola (E) na stanowiskach pracownika stwierdzono dla aparatów elektrochirurgicznych do 400 V/m, diatermii krótkofalowych (KF) do 220 V/m, zgrzewarek dielektrycznych do 240 V/m i wnętrza radiowych systemów antenowych UKF do 180 V/m. Największy zasięg stref ochronnych stwierdzono dla prototypowych urządzeń stosowanych w nauce, diatermii KF i zgrzewarek dielektrycznych. Najwyższą krotność przekroczenia NDN stwierdzono przy: zgrzewarkach dielektrycznych do 12, diatermiach KF do 11, diatermiach MF do 8. Wnioski Potwierdzono wysokie wartości natężenia PEM RF w środowisku pracy dla takich grup zawodowych jak fizjoterapeuci, operatorzy zgrzewarek dielektrycznych i pracownicy technicznych grup masztowych w obiektach radiokomunikacji (w tym stacji radiowych i telewizyjnych). Med. Pr. 2015;66(2):199–212
EN
Background Mobile telephones belong to the most frequently used personal devices. In their surroundings they produce the electromagnetic field (EMF), in which exposure range there are not only users but also nearby bystanders. The aim of the investigations and EMF measurements in the vicinity of phones was to identify the electric field levels with regard to various working modes. Material and Methods Twelve sets of DECT (digital enhanced cordless telecommunications) cordless phones (12 base units and 15 handsets), 21 mobile telephones produced by different manufactures, and 16 smartphones in various applications, (including multimedia) in the conditions of daily use in living rooms were measured. Measurements were taken using the point method in predetermined distances of 0.05–1 m from the devices without the presence of users. Results In the vicinity of DECT cordless phone handsets, electric field strength ranged from 0.26 to 2.30 V/m in the distance of 0.05 m – 0.18–0.26 V/m (1 m). In surroundings of DECT cordless telephones base units the values of EMF were from 1.78–5.44 V/m (0.05 m) to 0.19– 0.41 V/m (1 m). In the vicinity of mobile phones working in GSM mode with voice transmission, the electric field strength ranged from 2.34–9.14 V/m (0.05 m) to 0.18–0.47 V/m (1 m) while in the vicinity of mobile phones working in WCDMA (Wideband Code Division Multiple Access) mode the electric field strength ranged from 0.22–1.83 V/m (0.05 m) to 0.18–0.20 V/m (1 m). Conclusions The mean values of the electric field strength for each group of devices, mobile phones and DECT wireless phones sets do not exceed the reference value of 7 V/m, adopted as the limit for general public exposure. Med Pr 2015;66(6):803–814
PL
Wstęp Telefony komórkowe należą do najczęściej stosowanych urządzeń użytku osobistego. Urządzenia te wytwarzają w swoim otoczeniu pole elektromagnetyczne (PEM), w którego zasięgu oprócz ich użytkownika znajdują się także przebywające w pobliżu osoby postronne. Celem niniejszego badania i pomiarów PEM w otoczeniu ww. urządzeń było poznanie poziomu natężenia pola elektrycznego z uwzględnieniem różnego trybu pracy (rozmowa głosowa GSM (global system for mobile communications), WCDMA (wideband code division multiple access), przesyłanie danych). Materiał i metody Zbadano 12 zestawów (w tym 12 stacji bazowych i 15 słuchawek) telefonów bezprzewodowych systemu DECT (digital enhanced cordless telecommunications), 21 telefonów komórkowych różnych producentów, 16 smartfonów podczas różnych zastosowań, w tym multimedialnych, w warunkach codziennego stosowania, w pomieszczeniach mieszkalnych. Pomiary realizowano metodą punktową w ustalonych odległościach (0,05–1 m) od wolnostojącej obudowy badanego urządzenia, bez obecności użytkownika. Wyniki W otoczeniu słuchawek telefonów bezprzewodowych DECT natężenie pola elektrycznego wynosiło 0,26–2,3 V/m w odległości 0,05 m do 0,18–0,26 V/m w odległości 1 m, natomiast w otoczeniu ich stacji bazowych – 1,78–5,44 V/m w odległości 0,05 m do 0,19–0,41 V/m w odległości 1 m. W otoczeniu telefonów komórkowych pracujących w trybie GSM w warunkach rozmowy natężenie pola wynosiło 2,34–9,14 V/m w odległości 0,05 m do 0,18–0,47 V/m w odległości 1 m. Z kolei w trybie WCDMA w warunkach rozmowy natężenie pola wynosiło 0,22–1,83 V/m w odległości 0,05 m do 0,18–0,20 V/m w odległości 1 m. Wnioski Średnie natężenie pola elektrycznego dla poszczególnych grup urządzeń telefonów komórkowych i bezprzewodowych systemu DECT nie przekraczało wartości odniesienia – 7 V/m, przyjętej jako graniczna dla ekspozycji ludności. Med. Pr. 2015;66(6):803–814
EN
Background In the studies investigating the potential health effects of occupational exposure to electromagnetic fields (EMF), the key problem is the assessment of workers’ exposure. Electromagnetic fields exposure assessment requires determining maximum EMF levels, for the acute effect, and the dose absorbed, for the cumulative effect. A study was undertaken to determine EMF exposure in workers at broadcasting centers (BCs) in Poland. It was the first part of a comprehensive project on health effects of occupational exposure to EMF. Material and Methods The study was conducted in 4 selected BCs. Spot measurements of electric field strength (E), and the results of E measurements that were made in the past for occupational hygiene assessments, were used for determining workers’ exposure to electric field. The parameters considered were the maximum E value ($\text{E}_\text{max}$), the weighted average E value ($\text{E}_\text{avg}$) and the E lifetime dose ($\text{E}_\text{lifetime dose}$). Results In the group of workers examined, the E values did not exceed 16.7 V/m for Emax (the occupational exposure limit (OEL) for work shift in Poland is 20 V/m), 2.9 V/m for $\text{E}_\text{avg}$ and 1 500 000 (V/m)²×h for $\text{E}_\text{lifetime dose}$. Conclusions In view of the lack of dosimetry data, a retrospective assessment of BC workers’ exposure to very high frequency and ultra-high frequency EMF was conducted, which made it possible to estimate EMF lifetime dose for the workers. Since the EMF exposure levels at BCs did not exceed the admissible values, they can be considered safe to the workers’ health, according to the approach used for developing OELs for EMF exposure. Med Pr 2018;69(5):477–482
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.