Medycyna Pracy
|
2019
|
vol. 70
|
issue 6
669-673
EN
Background The method of measuring doses based on the thermoluminescence phenomenon is not an absolute method. For this reason, to obtain correct results, it is necessary to calibrate detectors in the known radiation field. This paper presents a method for calibrating thermoluminescent detectors used in the measurement of personal dose equivalents (Hp(0.07)) obtained by nuclear medicine facility personnel when handling the $\text{}^{99m} \text{Tc}$ radionuclide. Material and Methods The authors used self-developed high-sensitivity thermoluminescent detectors and a HF320C X-ray unit, as well as a rod phantom. Dosimeters were calibrated in accordance with the ISO 4037-3 standard. During the measurements a vial containing a $\text{}^{99m} \text{Tc}$ radionuclide with well-known activity was also used. The energy characteristics were supplemented by using a ¹³⁷Cs source (irradiator ⁶⁰Co/¹³⁷Cs). Results The value of the calibration coefficient for 118 keV energy energy was (1.90±0.02)×10⁻⁵ mSv/imp. Taking into account the correction factor specified for of 140 keV energy at 0.962, the value of the calibration coefficient for 140 keV energy was determined as (1.83±0.02)×10⁻⁵ mSv/imp. Conclusions Verification of the calibration coefficient determined for 140 keV energy carried out with a vial containing a $\text{}^{99m} \text{Tc}$ radionuclide confirmed the correctness of the procedure. Med Pr. 2019;70(6):669–73
EN
Background: Lead aprons, as a type of individual radiological shields, are designed to protect the body against the negative effects of ionizing radiation. In order for the individual shields to fulfill their task, the weakening of the X-ray beam should be as high as possible. Previous reports have indicated the possibility of significant defects even among newly purchased aprons. The aim of the study was to analyze the influence of storage conditions and usage time on the permeability of lead aprons. Material and Methods: The analysis covered 11 lead aprons used by the staff and patients of the Department of Radiodiagnostics and Interventional Radiology of the Central Clinical Hospital in Katowice, Poland. The dependent variable was the average pixel value, and the grouping variables included the storage method, age and thickness of the apron, and the type of its user. Results: Statistically significant differences were found between the weakening value of the X-ray beam of individual aprons, and their storage conditions and age. Conclusions: Aprons stored in a hanging position show a greater degree of weakening of the X-ray beam, and thus a higher degree of worker protection, compared to aprons stored otherwise. The age of the apron affects its protective properties.
PL
Wstęp: Fartuchy ołowiane – jako jeden z typów indywidualnych osłon radiologicznych – mają za zadanie chronić ciało przed szkodliwym działaniem promieniowania jonizującego. Aby osłony indywidualne spełniały swoje zadanie, wartość osłabienia wiązki promieniowania rentgenowskiego (RTG) powinna być jak najwyższa. Dotychczasowe doniesienia wskazują na możliwość występowania istotnych defektów nawet w nowo zakupionych fartuchach. Celem tej pracy była analiza wpływu warunków przechowywania i czasu użytkowania fartuchów ołowianych na wartość osłabienia przez nie wiązki promieniowania RTG. Materiał i metody: Analizie poddano 11 fartuchów ołowianych wykorzystywanych przez personel i pacjentów Zakładu Radiodiagnostyki i Radiologii Zabiegowej Uniwersyteckiego Centrum Klinicznego im. prof. K. Gibińskiego w Katowicach. Zmienną zależną była średnia wartość piksela, a za zmienne grupujące przyjęto sposób przechowywania fartucha, jego wiek i grubość oraz typ jego użytkownika. Wyniki: Wykazano istotne statystycznie różnice pomiędzy wartością osłabienia wiązki promieniowania RTG poszczególnych fartuchów a ich warunkami przechowywania i wiekiem. Wnioski: Fartuchy przechowywane w pozycji wiszącej wykazują większy stopień osłabienia wiązki promieniowania RTG, a tym samym lepszą ochronę pracownika, w stosunku do fartuchów składowanych w inny sposób. Wiek fartucha wpływa na jego właściwości ochronne.
PL
Wstęp Badania rentgenowskie wiążą się z narażeniem pacjentów na promieniowanie jonizujące. Wielkość narażenia zależna jest od wykonywanej procedury medycznej, stanu technicznego aparatu rentgenowskiego i warunków ekspozycji dobieranych przez techników rentgenowskich (rtg.). Celem badania było oszacowanie wejściowej dawki powierzchniowej (ESD), na którą są narażani pacjenci podczas badań rentgenowskich kończyn górnych i dolnych. Uzyskane wyniki powinny być brane pod uwagę przez lekarzy przy podejmowaniu decyzji o kierowaniu pacjentów na badanie rentgenowskie. Stan techniczny aparatów rtg. i sposób wykonania badania jest również istotny dla ochrony radiologicznej personelu medycznego. Materiał i metody Badaniami objęto 56 placówek medycznych zlokalizowanych na terenie województwa mazowieckiego, wyposażonych łącznie w 118 aparatów rentgenowskich. Pomiary dawek otrzymywanych przez pacjentów przeprowadzono, stosując autorskie akredytowane procedury badawcze. Wyniki Stwierdzono kilkunastokrotne różnice w wielkości dawek otrzymanych przez dorosłych pacjentów i kilkukrotne różnice w przypadku dzieci. Największa rozpiętość mierzonych dawek u pacjentów dorosłych dotyczyła radiografii kości udowej. Zmierzona ESD dla tej procedury wynosiła 70,9–765,2 μGy (średnia: 319,7 μGy). U dzieci największa rozpiętość mierzonych dawek dotyczyła radiografii kolana. Wejściowa dawka powierzchniowa u dzieci 5-letnich wynosiła 11,8–95,8 μGy (średnia: 48,9 μGy). Wnioski Niezbędne jest jak najszybsze wdrożenie w pracowniach rentgenowskich roboczych procedur badań diagnostycznych na podstawie obowiązujących w Polsce procedur wzorcowych. Med. Pr. 2016;67(3):321–326
EN
Background X-ray examination is associated with the patient’s exposure to ionizing radiation. The dose values depend on the type of the medical procedure used, the X-ray unit technical condition and exposure conditions selected by X-ray technicians. The aim of this study has been to assess the entrance surface dose (ESD) values received by patients during the limb X-ray examination. The results should help doctors in making the decision about sending patients for X-ray examination. At the same time the X-ray unit condition and examination method performance are important for the radiological protection of the medical staff. Material and Methods The study covered the total number of 118 X-ray units located in 56 public healthcare entities and private medical centers in the Masovian Voivodeship. The measurement of the radiation dose rate received by patients was based on our own research procedures. Results The research has found that there are even more than 10-fold differences in the dose values received by adult patients with several-fold differences in the case of children patients. The broadest dose value range for adult patients was related to femur radiography. The ESD values for this procedure ranged 70.9–765.2 μGy (with the average value of 319.7 μGy). The broadest dose value range for children was related to the knee radiography. The range for children aged 5 years old was 11.8–95.8 μGy (with the average value of 48.9 μGy). Conclusions It is essential to immediately implement X-ray room working procedures for the purpose of performing diagnostic examinations based on the existing model procedures. Med Pr 2016;67(3):321–326
EN
Background Some cardiac implantable electronic device (CIED) implantation procedures require the use of X-rays, which is reflected by such parameters as total fluoroscopy time (TFT) and dose-area product (DAP – defined as the absorbed dose multiplied by the area irradiated). Material and Methods This retrospective study evaluated 522 CIED implantation (424 de novo and 98 device upgrade and new lead placement) procedures in 176 women and 346 men (mean age 75±11 years) over the period 2012–2015. The recorded procedure-related parameters TFT and DAP were evaluated in the subgroups specified below. The group of 424 de novo procedures included 203 pacemaker (PM) and 171 implantable cardioverter-defibrillator (ICD) implantation procedures, separately stratified by single-chamber and dual-chamber systems. Another subgroup of de novo procedures involved 50 cardiac resynchronization therapy (CRT) devices. The evaluated parameters in the group of 98 upgrade procedures were compared between 2 subgroups: CRT only and combined PM and ICD implantation procedures. Results We observed differences in TFT and DAP values between procedure types, with PM-related procedures showing the lowest, ICD – intermediate (with values for single-chamber considerably lower than those for dual-chamber systems) and CRT implantation procedures – highest X-ray exposure. Upgrades to CRT were associated with 4 times higher TFT and DAP values in comparison to those during other upgrade procedures. Cardiac resynchronization therapy de novo implantation procedures and upgrades to CRT showed similar mean values of these evaluated parameters. Conclusions Total fluoroscopy time and DAP values correlated progressively with CIED implantation procedure complexity, with CRT-related procedures showing the highest values of both parameters. Med Pr 2017;68(3):363–374
PL
Wstęp Realizacja części procedur CIED (cardiac implantable electronic device – stałej elektroterapii serca) wymaga zastosowania promieniowania rentgenowskiego (rtg.), co znajduje odzwierciedlenie w czasie ekspozycji TFTs (total fluoroscopy times – łączny czas naświetlania) oraz wielkości dawki promieniowania rtg. wyemitowanej na skórę pacjenta (dose area product – DAP). Materiał i metody Badaniem retrospektywnym dotyczącym lat 2012–2015 objęto 522 procedury CIED (u 176 kobiet i 346 mężczyzn, średnia wieku: 75±11 lat), z których 424 były zabiegami pierwszorazowymi (de novo), a 98 powtórnymi (upgrade), wymagającymi wprowadzenia nowej elektrody i zmiany urządzenia. Zarejestrowane po ich realizacji parametry TFTs i DAP odniesiono do wymienionych poniżej grup. Grupę 424 zabiegów de novo tworzyły: 203 implantacje stymulatorów (pacemaker – PM), 171 implantacji kardiowerterów-defibrylatorów (implantable cardiowerter-defibrylator – ICD), w których obrębie niezależnie wyodrębniono układy 1- i 2-jamowe, oraz 50 implantacji układów resynchronizujących (cardiac resynchronization therapy – CRT). W przypadku grupy 98 procedur upgrade porównano parametry między 2 podgrupami zabiegów – tylko do CRT oraz tylko w obrębie PM i ICD. Wyniki Najniższe wartości TFTs i DAP towarzyszyły implantacjom PM, pośrednie – ICD, z wyraźnym wzrostem w przypadku układów 2-jamowych w stosunku do 1-jamowych. Najwyższe wartości TFTs i DAP cechowały zabiegi CRT. Zabiegom upgrade do CRT towarzyszyły 4-krotnie większe wartości TFTs i DAP w porównaniu z upgrade niezwiązanym z CRT. W przypadku zabiegów CRT de novo i CRT upgrade średnie wartości mierzonych parametrów były zbliżone. Wnioski Czas ekspozycji i wielkość DAP pozostawały dodatnio związane z zaawansowaniem procedury CIED, przy czym zabiegi z zakresu CRT wyróżniały się ich największymi wartościami. Med. Pr. 2017;68(3):363–374
EN
Background The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes. Material and Methods Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films. Results The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs. Conclusions The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491–496
PL
Wstęp Stosowanie w procedurach stomatologicznych promieniowania rentgenowskiego (rtg.) powoduje narażenie pacjenta na promieniowanie jonizujące. Wielkość tego narażenia zależy przede wszystkim od parametrów stosowanych przy prześwietleniu zęba. Celem badań było określenie wielkości dawek, na jakie narażeni są pacjenci, oraz ocena stanu technicznego aparatów rtg. Materiał i metody Badaniami ankietowymi objęto 1700 gabinetów stomatologicznych. Ankiety odesłało 740 jednostek. Pomiary bezpośrednie wykonano w 100 gabinetach. Pomiary wykonano za pomocą detektorów termoluminescencyjnych i klisz rtg. Wyniki W przeprowadzonych badaniach stwierdzono, że najczęściej stosowany czas ekspozycji wynosi 0,22±0,16 s. Średnia dawka wejściowa dla parametrów najczęściej stosowanych przez stomatologów to 1,7±1,4 mGy. Średnia wydajność lampy rtg. oszacowana na podstawie wykonanych ekspozycji wynosi 46,5±23,7 μGy/mAs. Wnioski Jak wynika z przeprowadzonych badań, znakomita większość aparatów rtg. punktowych spełnia wymagania określone w przepisach. Med. Pr. 2017;68(4):491–496