Objectives While working with cyclotrons used for the production of radiopharmaceuticals, workers can experience significant exposure to the adverse effects of ionizing radiation. The aim of this paper was to determine the typical level of such exposure received by such personnel while servicing cyclotrons. Material and Methods Exposure was assessed using TLD detectors placed in an anthropomorphic phantom, as well as dose meter to determine whole body and eye lens exposure. The phantom was placed in locations receiving the greatest exposure to ionizing radiation during service activities. The time spent by employees during servicing was assessed based on routine visits by service technicians. The obtained results were compared with readings of detectors worn by employees during service activities. Results The highest equivalent doses in the thoracic area were found to be received by the lungs (211.16 μSv/year). In the head and neck area, the highest dose was measured in the eye lens (3410 μSv/year). The effective dose for the whole body was found to be 1154.4 μSv/year, based on the phantom, and 149 μSv per service visit (1192 μSv/year), based on the dose meters carried by the workers. Conclusions Service workers are exposed to significant doses of ionizing radiation, representing a clear radiological protection issue. To reduce exposure to eye lenses, it is recommended to use protective goggles when working with highly-radioactive elements.
Medycyna Pracy
|
2018
|
vol. 69
|
issue 3
317-327
EN
Background A radiopharmaceutical is a combination of a non-radioactive compound with a radioactive isotope. Two isotopes: technetium- 99m ($ \text{}^\text{99m}\text{Tc} $) and fluorine-18 ($ \text{}^\text{18}\text{F} $) are worth mentioning on the rich list of isotopes which have found numerous medical applications. Their similarity is limited only to the diagnostic area of applicability. The type and the energy of emitted radiation, the half-life and, in particular, the production method demonstrate their diversity. The $ \text{}^\text{99m}\text{Tc} $ isotope is produced by a short-lived nuclide generator – molybdenum-99 ($ \text{}^\text{99}\text{Mo} $)/$ \text{}^\text{99m}\text{Tc} $, while $ \text{}^\text{18}\text{F} $ is resulting from nuclear reaction occurring in a cyclotron. A relatively simple and easy handling of the $ \text{}^\text{99}\text{Mo} $ \text{}^\text{99m}\text{Tc} $ generator, compared to the necessary use a cyclotron, seems to favor the principle of optimizing the radiological protection of personnel. The thesis on the effect of automation of both the $ \text{}^\text{18}\text{F} $ isotope production and the deoxyglucose labelling process on the optimization of radiological protection of workers compared to manual procedures during handling of radiopharmaceuticals labelled with $ \text{}^\text{99m}\text{Tc} $ need to be verified. Material and Methods Measurements of personal dose equivalent Hp(0.07) were made in 5 nuclear medicine departments and 2 radiopharmaceuticals production centers. High-sensitivity thermoluminescent detectors (LiF: Mg, Cu, P – MCP-N) were used to determine the doses. Results Among the activities performed by employees of both $ \text{}^\text{18}\text{F} $-fluorodeoxyglucose ($ \text{}^\text{18}\text{F} $-FDG) production centers and nuclear medicine departments, the manual quality control procedures and labelling of radiopharmaceuticals with $ \text{}^\text{99m}\text{Tc} $ isotope manifest the greatest contribution to the recorded Hp(0.07). Conclusions The simplicity of obtaining the $ \text{}^\text{99m}\text{Tc} $ isotope as well as the complex, but fully automated production process of the $ \text{}^\text{18}\text{F} $-FDG radiopharmaceutical optimize the radiation protection of workers, excluding manual procedures labelling with $ \text{}^\text{99m}\text{Tc} $ or quality control of $ \text{}^\text{18}\text{F} $-FDG. Med Pr 2018;69(3):317–327
PL
Wstęp Radiofarmaceutyk to produkt będący połączeniem niepromieniotwórczego związku chemicznego i znacznika izotopowego. Na bogatej liście izotopów mających zastosowane w medycynie na uwagę zasługują 2 – technet-99m ($ \text{}^\text{99m}\text{Tc} $) i fluor-18 ($ \text{}^\text{18}\text{F} $). Ich podobieństwo ogranicza się jedynie do diagnostycznego obszaru stosowalności, a dzieli je m.in. rodzaj i energia emitowanego promieniowania, czas połowicznego rozpadu czy w szczególności sposób produkcji. Izotop $ \text{}^\text{99m}\text{Tc} $ uzyskuje się dzięki generatorom nuklidów krótkożyciowych – molibdenu-99 ($ \text{}^\text{99}\text{Mo} $)/$ \text{}^\text{99m}\text{Tc} $, a $ \text{}^\text{18}\text{F} $ powstaje w reakcji jądrowej zachodzącej w cyklotronie. Stosunkowo łatwy sposób obsługi generatora $ \text{}^\text{99}\text{Mo} $/$ \text{}^\text{99m}\text{Tc} $ w porównaniu z koniecznością wykorzystania cyklotronu wydaje się sprzyjać zasadzie optymalizacji ochrony radiologicznej personelu. Weryfikacja tezy dotyczącej wpływu automatyki zarówno produkcji znacznika $ \text{}^\text{18}\text{F} $, jak i procesu znakowania deoksyglukozy na zoptymalizowanie ochrony radiologicznej pracowników w porównaniu z manualnymi procedurami wykonywanymi podczas znakowania preparatów izotopem $ \text{}^\text{99m}\text{Tc} $. Materiał i metody Dawki równoważne Hp(0,07) zmierzono w 5 zakładach medycyny nuklearnej i 2 ośrodkach produkujących znaczniki pozytonowe, w szczególności $ \text{}^\text{18}\text{F} $. W pomiarach dozymetrycznych wykorzystano wysokoczułe detektory termoluminescencyjne wykonane z fluorku litu (LiF: Mg, Cu, P – MCP-N). Wyniki Wśród czynności wykonywanych przez pracowników zarówno placówek produkujących $ \text{}^\text{18}\text{F} $-fluorodeoksyglukozę ($ \text{}^\text{18}\text{F} $-FDG), jak i zakładów medycyny nuklearnej manualne procedury kontroli jakości oraz znakowanie preparatu mają największy wkład do zarejestrowanych wartości dawek Hp(0,07). Wnioski Prosty sposób uzyskania znacznika $ \text{}^\text{99m}\text{Tc} $ podobnie jak złożony (choć w pełni zautomatyzowany) proces produkcji $ \text{}^\text{18}\text{F} $-FDG optymalizuje ochronę radiologiczną personelu z wyłączeniem manualnych procesów znakowania związków chemicznych $ \text{}^\text{99m}\text{Tc} $ bądź kontroli jakości $ \text{}^\text{18}\text{F} $-FDG. Med. Pr. 2018;69(3):317–327